Specifications
- Measuring Method : Dual Slope A/D Conversion
- Sampling Rate : 2.5 Samples per Second
- Display Type : 14.2mm / 0.56" Digit Height, Red LED (Standard)
- Maximum Display : 1999 Counts for 3½Digit Meters
- Resolution : 0.001 to 1 Count for 3½depending on the Range
- Polarity Indication : "-" is indicated for Negative Input
- Decimal Selection : Field Selectable
- Over Range Indication : "1" or "-1" for 3½ Digit Meters
- Maximum Overload : Voltage : 1.2 times continuous, Current : 2 times continuous
- Environment : Calibration : 27°C±5°C, Operating : 0 to 50°C, RH < 70%, Storage : -10 to 60°C, RH < 70%
- VA Burden (Typical) : Auxiliary : < 1.0VA, Voltage Input : < 1.0VA, Current Input : < 1.0VA
- Faceplate / Lens : Red Antiglare Faceplate with Annunciators
- Dielectric Strength : 2.5 kV at 50Hz for 1 min. between Case - Terminals
- Case / Housing : DIN Black ABS, Dimension as per DIN Material 43700
- Mounting Clamps : Sturdy, Moulded ABS with suitable Hardware
- Connectors : Terminal Block : Thermoplastic (UL 94V-0) with Tin Plated Brass Terminals
- Display Stability : Within ± 2 Digits
Ordering Information
Model, Input Range & Scale Display
Download catalog for complete technical specifications